Implantable Pressure Sensor Encapsulation for Ventricular Assist Device Control

Printed Book
SR 302
Inclusive of VAT
Sold as: EACH
SR18Per Month/24 months
Author:Dupuch, Matthias Alexander
Date of Publication: 2024
Book classification:Medical Books,English Books,
No. of pages:194 Pages
Format:Paperback

This book is printed on demand and is non-refundable after purchase

Available Formats :

Printed Book

It will be sent to your address

SR302
Incl. VAT

Choose your delivery preference

Or

About this Product

Autonomous feedback controlled ventricular assists device (VAD) operation promises a plethora of benefits such as increased patient safety, comfort, and reduced healthcare costs. Current generation VADs operate at static pump speeds due to the lack of available biocompatible, long-term stable pressure sensor systems. In this thesis, a pressure sensor encapsulation was developed and integrated in an inflow cannula for a VAD and in an implantable testing platform for animal trials. The encapsulation uses a media separating diaphragm embedded in a Parylene C coating. The approach is expanded to enable optimized diaphragm shapes, which allow significantly better control over the final device characteristics, especially the temperature cross sensitivity. Furthermore, a production processes was developed to minimize assembly induced internal overpressure. The produced capsules showed excellent pressure transmission of more than 99.7 % and a temperature cross sensitivity of less than 266 Pa from 35 C to 42 C for most capsules. However, a large temperature cross sensitivity was observed from room to body temperature in some capsules, adding relevant drift of 750 Pa (75 % quartile) after 42 days to the measurement. The observed drift is related to the viscoelastic nature of the Parylene C diaphragm and the capsule-to-capsule variation is attributed to production process variations, which can be further optimized. Systematic errors in the pressure transmission, temperature cross sensitivity (TCS), and drift were extracted and correction approaches for each were developed. This enabled the reduction of the pressure transmission error by 50 % by linear correction. A differential measurement approach reduced the temperature cross sensitivity to less than 70 Pa from 35 C to 42 C and drastically reduced the temperature induced drift to 300 Pa (75 % quartile) after a jump from room to body temperature. Half of all sensors even remained within a +- 100 Pa window in the same tim
Show more

Specifications

SKU9783866288348
Manufacturer Number9783866288348
year published2024
Show more

Report an issue with this product.

Customer Reviews