مكتبة جرير

Implantable Pressure Sensor Encapsulation for Ventricular Assist Device Control

كتاب مطبوع
302ر.س.
شامل ضريبة القيمة المضافة
وحدة البيع: EACH
18ر.س.شهرياً/24 شهر
المؤلف:Dupuch, Matthias Alexander
تاريخ النشر: 2024
تصنيف الكتاب:الكتب الطبية,الكتب الانجليزية,
عدد الصفحات:194 Pages
الصيغة:غلاف ورقي
هذا الكتاب يُطبع عند الطلب وغير قابل للاسترجاع بعد الشراء

الصيغ المتوفرة:

كتاب مطبوع

سيتم إرسال الطلب الى عنوانك

302ر.س.
شامل الضريبة

حدد خيار التوصيل الذي تفضله

أو

عن المنتج

Autonomous feedback controlled ventricular assists device (VAD) operation promises a plethora of benefits such as increased patient safety, comfort, and reduced healthcare costs. Current generation VADs operate at static pump speeds due to the lack of available biocompatible, long-term stable pressure sensor systems. In this thesis, a pressure sensor encapsulation was developed and integrated in an inflow cannula for a VAD and in an implantable testing platform for animal trials. The encapsulation uses a media separating diaphragm embedded in a Parylene C coating. The approach is expanded to enable optimized diaphragm shapes, which allow significantly better control over the final device characteristics, especially the temperature cross sensitivity. Furthermore, a production processes was developed to minimize assembly induced internal overpressure. The produced capsules showed excellent pressure transmission of more than 99.7 % and a temperature cross sensitivity of less than 266 Pa from 35 C to 42 C for most capsules. However, a large temperature cross sensitivity was observed from room to body temperature in some capsules, adding relevant drift of 750 Pa (75 % quartile) after 42 days to the measurement. The observed drift is related to the viscoelastic nature of the Parylene C diaphragm and the capsule-to-capsule variation is attributed to production process variations, which can be further optimized. Systematic errors in the pressure transmission, temperature cross sensitivity (TCS), and drift were extracted and correction approaches for each were developed. This enabled the reduction of the pressure transmission error by 50 % by linear correction. A differential measurement approach reduced the temperature cross sensitivity to less than 70 Pa from 35 C to 42 C and drastically reduced the temperature induced drift to 300 Pa (75 % quartile) after a jump from room to body temperature. Half of all sensors even remained within a +- 100 Pa window in the same tim
عرض أكثر

المواصفات

رقم الصنف9783866288348
رقم المصنع9783866288348
تاريخ النشر2024
عرض أكثر

أبلغ عن مشكلة مع هذا المنتج

مراجعات العملاء