مكتبة جرير

A Polymer Cochlear Electrode Array: Atraumatic Deep Insertion

Tripolar Stimulationand Long-Term Reliability

كتاب مطبوع
604ر.س.
شامل ضريبة القيمة المضافة
وحدة البيع: EACH
36ر.س.شهرياً/24 شهر
المؤلف:Gwon, Tae Mok
تاريخ النشر: 2018
تصنيف الكتاب:كتب الهندسة,الكتب الانجليزية,
عدد الصفحات:116 Pages
الصيغة:غلاف ورقي
هذا الكتاب يُطبع عند الطلب وغير قابل للاسترجاع بعد الشراء

الصيغ المتوفرة:

كتاب مطبوع

سيتم إرسال الطلب الى عنوانك

604ر.س.
شامل الضريبة

حدد خيار التوصيل الذي تفضله

أو

عن المنتج

This book describes the design, fabrication and evaluation of a polymer-based neural interface for a cochlear electrode array, reviewed in terms of fabrication process, functionality, and reliability. Polymer-based devices have attracted attention in the neural prosthetic field due to their flexibility and compatibility with micro-fabrication process. A liquid crystal polymer (LCP) is an inert, highly water-resistant polymer suitable for the encapsulation of electronic components and as a substrate material for fabricating neural interfaces. The author has designed, fabricated, and evaluated an LCP-based cochlear electrode array for an improved polymer-based cochlear implant. The thesis deals with 3 key topics: atraumatic deep insertion, tripolar stimulation, and long-term reliability. Atraumatic insertion of the intracochlear electrode and resulting preservation of residual hearing have become essential in state-of-the-art cochlear implantation. A novel tapered design of an LCP-based cochlear electrode array is presented to meet such goals. For high-density and pitch-recognizable cochlear implant, channel interaction should be avoided. Local tripolar stimulation using multi-layered electrode sites are shown to achieve highly focused electrical stimulation. This thesis addresses another vital issue in the polymer-based neural implants: the long-term reliability issue. After suggesting a new method of forming mechanical interlocking to improve polymer-metal adhesion, the author performs accelerating aging tests to verify the methods efficacy. The aforementioned three topics have been thoroughly examined through various in vitro and in vivo studies. Verification foresees the development of LCP-based cochlear electrode array for an atraumatic deep insertion, advanced stimulation, and long-term clinical implant.

عرض أكثر

المواصفات

رقم الصنف9789811344244
رقم المصنع9789811344244
تاريخ النشر2018
عرض أكثر

أبلغ عن مشكلة مع هذا المنتج

مراجعات العملاء