Jarir Logo

Flow and Mixing Optimization of an Existing Biogas Plant through CFD Simulation and Velocity Measurements Prepared

Printed Book
SR 293
Inclusive of VAT
Sold as: EACH
SR17Per Month/24 months
Author:Yaghi, Obada
Date of Publication: 2019
Book classification:Engineering,English Books,
No. of pages:102 Pages
Format:Paperback

This book is printed on demand and is non-refundable after purchase

Available Formats :

Printed Book

It will be sent to your address

SR293
Incl. VAT
Or

About this Product

Bachelor Thesis from the year 2016 in the subject Engineering - Mechanical Engineering, grade: 94%, German Jordanian University (hosted by Hamburg University of Technology), language: English, abstract: This research project enables further development and improvement of the mixing efficiency in an existing biogas plant, by utilizing CFD simulation as well as a newly developed flow sensor in addition to supportive laboratory tests. The flow was analyzed considering the following variables: The mixing time, the Dry Matter (DM) content, the positioning of the agitators and how it can be related to the amount of velocity dead-zones. The velocity measurements took place at the biogas plant of the company Ardestorfer Bioenergie GmbH in the district of Buxtehude. The current plant capacity is approximately 1.6 MWel using animals manure, energy crops as well as agricultural residuals. In order to be able to perform the CFD simulation, a complete 3D model had to be done of the examined fermenter and the mixing agitators. Moreover, the current setup including fluid properties, boundary and initial conditions had to be taken into consideration. Velocity measurements were used as a validation approach for the simulation results, furthermore to acquire an overview of the flow behavior over the investigated mixing period. Firstly, it was found that at higher DM content the flow seemed to be more stable, and the velocity values get quite higher at the examined points. Moreover, at higher DM content (9.35% compared with 8.8%) the velocity dead-zones seemed to be approximately 70% less. Secondly, another approach was considered to improve the mixing and to minimize the dead-zones by changing the position of the main agitator. The new scenario showed fewer dead-zones by approximately 65% according to the CFD model. Thirdly, at all scenarios and setups, the flow seemed to reach the maximum possible velocity, and rather motion distribution after 150-180 seconds. Showing no remark
Show more

Specifications

SKU9783668925755
Manufacturer Number9783668925755
year published2019
Show more

Report an issue with this product.

Customer Reviews